Surveys and reports — know what you have.

Many buildings don't have a clear list of their pumps, tanks and fire systems, or the design records that go with them. A survey fixes that: every system found, recorded, photographed and assessed, with a plain report on what needs doing and what it will cost.

In short

PMP surveys a building's pumps and fire water systems and writes up what is there, its condition and what needs doing — useful when you take over a building with no records.

In plain words: A condition survey is a one-off look at every system in a building, written up so you know where you stand.

Area: all of Western Australia · Updated

What a survey covers

Fire pumps, sprinklers, hydrants, hose reels and fire water tanks · pressure, sewer and stormwater pumps · storage tanks · control panels · backflow devices · water treatment systems.

What you get

An asset list of every system and major component, with photos · the condition of each · defects and missing items, sorted by how urgent they are · recommendations and prices · the records that are missing and how to rebuild them.

Missing design records

AS 1851 calls the original design and commissioning figures "baseline data" — the numbers every later test is compared against. If they're missing, that is itself reported as a non-conformance. Where they can't be found, we help establish them from testing, so future results mean something.

Taking over a building

New strata manager, new facility manager, new owner? A survey at the start tells you what you've inherited before it becomes your responsibility.

What you receive

A written survey report with photographs. Workmanship guaranteed for 12 months.

Your paperwork, job by job

Photos that help us price it

  1. Whatever records exist
  2. The plant room
  3. The pump nameplates

Send them with the quote form, text or WhatsApp them to 0439 729 553, or email support@pmpwa.net.au. Already have a service report or defect list? Attach that too.

Related questions

Free · Reply within one business day

Get a free second opinion on your last service report, or a second quote.

Upload it and PMP will tell you what's overdue under AS 1851, which defects are still open and what's close to the end of its life. Already have a quote? We'll give you a second one to compare.

Upload Your Report

Questions people ask

We've taken over a building with no records — where do we start?

Start with a survey. Every system is found, recorded, photographed and assessed, so you know what you've inherited before it becomes your responsibility.

What goes in the logbook?

A record of every routine service activity and its result, for each fire system. Hose reels and hydrant valves use tags or labels with summary records.

What does a survey cover?

Fire pumps, sprinklers, hydrants, hose reels and fire water tanks, building pumps, storage tanks, control panels, backflow devices and water treatment systems — with an asset list, photos, condition, defects, and recommendations with prices.