Service agreements — the whole plant room, on one schedule.
A service agreement puts every system in the building on the right schedule, done by the same team, with the records kept properly. Fire systems follow AS 1851 — the Australian Standard for routine service of fire protection systems. Building pumps follow the schedule their equipment needs. One agreement covers both.
In short
PMP services a building's fire systems at the intervals AS 1851-2012 sets — monthly, six-monthly, yearly and five-yearly — and its pumps on the same visits, with one report each time.
In plain words: Routine service is the regular checking and testing AS 1851 sets for each fire system, at fixed intervals.
Area: all of Western Australia · Updated
What's included
| System | Serviced |
|---|---|
| Fire pumps | Monthly, six-monthly, yearly (including a full flow test) and five-yearly |
| Sprinklers | Monthly, six-monthly, yearly, five-yearly, with head sampling from 25 years |
| Hydrants and boosters | Six-monthly, yearly, and five-yearly with a boosted flow test |
| Hose reels | Six-monthly and yearly |
| Fire water tanks | Monthly, six-monthly, yearly, and a drain and clean every ten years |
| Special hazard systems | Monthly, six-monthly, yearly and ten-yearly |
| Pressure, sewer, stormwater and other building pumps | Every six months, or every three months where the pumps work exceptionally hard |
| Backflow devices | Every 12 months, with the test report lodged |
What you get
Service records, reports and defects for every visit, kept in our in-house portal.
Logbooks kept up to date for every fire system, as AS 1851 requires.
Defects reported the right way. A critical defect — one that stops a system working — is reported to you before we leave site and confirmed in writing within 24 hours. Other defects and missing items are reported within a week.
A yearly condition report for each building: what was serviced, what's outstanding, and the state of each system.
A price for anything that needs fixing, for you to approve before we do it.
What the law asks of building owners in WA
Under regulation 48A of the Building Regulations 2012 (WA), the owner of an existing Class 2 to 9 building must keep its safety measures — which include its fire protection — capable of performing to the standard the building was approved to. The penalty for not doing so is up to $5,000.
In practice, that means the systems have to be serviced, the faults fixed, and the records kept to show it. That's what a service agreement is for.
This is general information about the regulations, not legal advice.
Taking over from another contractor
Send us the last service reports and logbooks and your renewal date. We'll pick up the schedule from where it is, and tell you straight away if anything is overdue or missing.
Building managers: one agreement, one team, one report per visit — for a single building or a portfolio.
Fire companies: we deliver the routine service on your agreements, to your schedule, in your paperwork.
What you receive
An AS 1851 service record and logbook entry each visit; a yearly condition report. Workmanship guaranteed for 12 months.
Photos that help us price it
- The last service report
- The logbook's last page
- The contract renewal date
Send them with the quote form, text or WhatsApp them to 0439 729 553, or email support@pmpwa.net.au. Already have a service report or defect list? Attach that too.
Related questions
- What is AS 1851?
The Australian Standard for routine service of fire protection systems and equipment. It sets what is inspected, tested and maintained, how often, and what records and reports are kept. The current edition is AS 1851-2012.
- What is a yearly condition report?
A report AS 1851-2012 requires once a year for each building. It summarises the year's servicing, lists outstanding defects and non-conformances, and states the condition of each system.
- Who is responsible for fire system servicing?
AS 1851 calls them the "responsible entity" — typically the building owner, the occupier, or the owner's agent. In a strata building, usually the strata company.
- What do WA building owners have to do about fire safety?
Under regulation 48A of the Building Regulations 2012 (WA), owners of existing Class 2 to 9 buildings must keep the building's safety measures able to perform to the standard the building was approved to. The penalty is up to $5,000. This is general information, not legal advice.
What our clients say
As a project and building manager, I need trades I can hand a job to and not have to chase. PMP Plumbing & Fire Services look after both the plumbing and the fire services across the buildings we manage — routine maintenance, breakdowns and project work, from pumps and hot water to sprinklers, hydrants and tanks. They turn up when they say they will, keep me informed, work safely around occupied buildings, and hand over clear reports and paperwork at the end. Having one contractor who covers all of it makes our job much simpler. I'd recommend PMP to any builder or building manager.
Free · Reply within one business day
Get a free second opinion on your last service report, or a second quote.
Upload it and PMP will tell you what's overdue under AS 1851, which defects are still open and what's close to the end of its life. Already have a quote? We'll give you a second one to compare.
Questions people ask
What does AS 1851 require for our building?
AS 1851 is the Australian Standard for routine service of fire protection systems. It sets what is inspected, tested and maintained, how often, and what records are kept — and each system in your building has its own section.
Can you take over from our contractor?
Yes. Send us the last service reports, logbooks and your renewal date. The schedule is picked up from where it is, and you're told straight away if anything is overdue or missing.
Can one agreement cover several buildings?
Yes. One agreement can cover a single building or a portfolio, with one team and one report per visit.
Is AS 1851 compulsory in WA?
WA law requires owners to keep fire safety measures working to the standard the building was approved to. AS 1851 is the Australian Standard the industry uses to show routine servicing has been done properly.
Who is responsible for having the systems serviced?
The building owner, or whoever the owner has made responsible — often the strata company, the tenant under the lease, or a managing agent.
What if some records are missing?
Missing records are themselves reported as a non-conformance under AS 1851. We'll tell you what's missing and help rebuild it.