Fire service fitouts in existing buildings.
New walls, a new ceiling or a change of use usually means the fire services have to change too — sprinkler heads moved or added, hydrant or hose reel coverage checked. We do that work in buildings that stay open while it happens.
In short
PMP changes sprinklers, hydrants and fire services for office and shop fitouts across WA, designs the changes in-house, and has fire systems back in service at the end of every working day.
In plain words: A fitout is the work that turns an empty floor or shop into a finished space, which often means moving sprinkler heads.
Area: all of Western Australia · Updated
What we do
Look at the drawings and the existing system · design the changes in-house · move, add or remove sprinkler heads and pipework · adjust hydrant and hose reel work where needed · test the changed system · put it back in service and hand over the records.
While work is under way
Part of the fire system may need to be isolated while we work. We keep that to the smallest area for the shortest time, agree it with the site first, and put it back in service at the end of each day.
For builders
Bring us in when the ceiling layout is drawn, not once it is installed. Moving a sprinkler head is simple on a drawing and expensive through a finished ceiling.
Fire companies: fitout work on your client's sites, as PMP or as you.
Building managers: tell us before the builder starts, and we'll keep the building protected while the work goes on.
What you receive
Design drawings, and the service record once the system is back in service. Workmanship guaranteed for 12 months.
Photos that help us price it
- The fitout plan
- The ceiling showing the existing heads
Send them with the quote form, text or WhatsApp them to 0439 729 553, or email support@pmpwa.net.au. Already have a service report or defect list? Attach that too.
Related questions
- Can we move sprinkler heads for a fitout?
Yes, but the change has to be checked against the system's design, done by a fire services contractor, and tested before the system goes back in service. New walls and ceilings can leave areas without cover if heads are simply moved to suit the ceiling grid.
Questions people ask
Will the building be protected while you work?
Yes. Any isolation is kept to the smallest area for the shortest time, agreed with the site first, and the fire system is put back in service at the end of every working day.
Do you design the changes?
Yes. Fitout changes are designed in-house in Revit, and PMP is responsible for the design.
When should a builder bring you in?
When the ceiling layout is drawn, not once it is installed. Moving a sprinkler head is simple on a drawing and expensive through a finished ceiling.
Do hydrants and hose reels need changing in a fitout too?
Sometimes. New walls, a new ceiling or a change of use can mean hydrant or hose reel coverage needs checking and adjusting, and PMP does that as part of the fitout work.