Fire pump servicing and overhauls.

Routine servicing is what makes a fire pump start when it's needed. We service diesel and electric fire pumps and their controllers on a set schedule, run them under test, and tell you in writing what we found.

In short

Under AS 1851-2012 a fire pump is run monthly and flow tested yearly, with additional five-yearly work. PMP does all of it, records every run, and services the pump room on the same visit.

In plain words: A churn test runs the pump with little or no water flowing; a flow test proves it delivers its rated flow.

Area: all of Western Australia · Updated

What a routine service covers

  • Starting. The pump is started from its controller, and started automatically by dropping system pressure — the way it would start in a fire.
  • Running. We run it and record pressures, speed, temperatures and anything unusual.
  • Diesel engines. Batteries and charger, fuel level and condition, oil, coolant, belts, hoses and exhaust.
  • Electric motors. Motor, starter and controls.
  • Valves, gauges and switches. The valves that must be open are open, the gauges read true, the pressure switches start the pump when they should.
  • The report. What we checked, what we found, what we couldn't check, and what needs fixing.

How often

Fire pumps are serviced on the schedule in Australian Standard AS 1851-2012, Section 3:

How oftenWhat's done
Every monthChecks, then an automatic start on a pressure drop and a manual restart. A diesel runs for at least 10 minutes and must reach full speed within 15 seconds; an electric pump runs for at least 3 minutes. Pressures, run time and readings are recorded.
Every six monthsThe monthly work, plus running electric pumps on their alternative power supply where one is fitted.
Every yearA full flow test (below), plus a full service: diesel oil and filters changed, fuel checked, cooling system flushed and tested; electric contacts, couplings and bearings checked; valves and relief settings proved.
Every five yearsPump glands repacked; relief, cooling and pressure-regulating valves overhauled; stop valves repacked; diesel air filters replaced.

Diesel engine-starting batteries are replaced at least every two years, whatever condition they seem to be in.

The yearly flow test

Test runs prove the pump starts and makes pressure. A flow test proves it can deliver water at the flow the building was designed for. It's part of the schedule, and it's the test most likely to find a worn pump.

Overhauls

Every five years the schedule calls for bigger work on the pump and its valves, in addition to the yearly service. We plan overhauls around the building so the fire system is out of service for as short a time as possible, and we tell the site before it is.

Diesel fuel

Diesel that sits in a tank for years collects water and can grow a sludge of bacteria and fungus — often called "diesel bug". It blocks filters and can stop an engine at the worst moment. We check fuel condition at every diesel service and tell you when it needs treating or replacing.

What you get

A written report after every visit: pump and engine details, run readings, what we found, photos, and a price for anything that needs fixing. You approve the work before we do it.

Brands we service

Southern Cross · Pentair Aurora · Fairbanks Nijhuis · NM Fire · NAFFCO · Fire Driver engines · National Motors · Fireguard controllers

And most other makes — if it pumps water in a building, we service and repair it. Send a photo of the nameplate if you are not sure.

What you receive

An AS 1851 service record and logbook entry; a yearly condition report. Workmanship guaranteed for 12 months.

Your paperwork, job by job

Photos that help us price it

  1. The pump and engine nameplates
  2. The logbook's last page

Send them with the quote form, text or WhatsApp them to 0439 729 553, or email support@pmpwa.net.au. Already have a service report or defect list? Attach that too.

Related questions

Free · Reply within one business day

Get a free second opinion on your last service report, or a second quote.

Upload it and PMP will tell you what's overdue under AS 1851, which defects are still open and what's close to the end of its life. Already have a quote? We'll give you a second one to compare.

Upload Your Report

Questions people ask

How often does a fire pump need testing in WA?

Fire pumps follow the AS 1851-2012 schedule: a test run every month, extra checks every six months, a full flow test and full service every year, and overhaul work every five years.

How long does a diesel pump run each month?

At least 10 minutes, and it must reach full speed within 15 seconds (AS 1851-2012). An electric fire pump runs for at least 3 minutes.

What happens at the yearly flow test?

The pump is run to prove it can deliver water at the flow the building was designed for, not just start and make pressure. Hydrant pumps are run at 130% of their duty flow, and the readings are compared with the design figures and previous tests.

When are the batteries replaced?

Diesel engine-starting batteries are replaced at least every two years under AS 1851-2012, whatever condition they seem to be in.

Will the fire system be out of service while you work?

Only for as long as necessary, and never without notifying the site first. For longer work we plan it with you in advance.

Can you take over mid-contract?

Yes. Send us the last service report and we'll pick up the schedule from there.

Do you service pumps another company installed?

Yes. Most of the pumps we service were installed by others.