Fire pumps — serviced, tested and repaired.

A fire pump gives the sprinklers and hydrants the pressure and flow they need when the water main can't. It can sit still for months and then has to start first time, every time. Keeping it ready to do that is the job.

Fire pumps are where PMP started. It's the work we know best.

In short

PMP services, tests and repairs diesel and electric fire pumps, jockey pumps and their controllers across WA, to AS 1851-2012, for building owners and for fire companies. Breakdowns 24/7.

In plain words: A fire pump boosts the water pressure in a building's sprinklers or hydrants when the town supply alone isn't enough.

Area: all of Western Australia · Updated

Diesel fire pumps

A diesel engine that drives the pump, so it keeps running if the building loses power. The parts that usually fail are the ones that sit idle: the starting batteries and charger, the fuel in the tank, the coolant, belts and hoses. We service the engine and the pump together, and run them the way they'll have to run in a fire.

Electric fire pumps

An electric motor that drives the pump, started by its own controller. We check the motor, the starter and the controls, and prove the pump starts on its own when system pressure drops.

Jockey pumps

A small pump that keeps the system topped up to pressure, so the main fire pump doesn't start every time a little pressure is lost. If your jockey pump is starting often, something is losing pressure — and the cause should be found before it gets worse.

Controllers

The control panel decides when the pump starts, keeps it running, and tells you when something is wrong. We service, fault-find, repair and replace fire pump controllers, and check the pressure switches that tell them when to start.

Fire companies: we service and repair fire pumps on your contracts, as PMP or as you.

Building managers: we'll look after the fire pump and the building pumps beside it on one visit.

Brands we service

Southern Cross · Pentair Aurora · Fairbanks Nijhuis · NM Fire · NAFFCO · Fire Driver engines · National Motors · Fireguard controllers

And most other makes — if it pumps water in a building, we service and repair it. Send a photo of the nameplate if you are not sure.

What you receive

An AS 1851 service record and logbook entry for each visit. Workmanship guaranteed for 12 months.

Your paperwork, job by job

Photos that help us price it

  1. The pump and engine nameplates
  2. The controller screen
  3. The last service report page

Send them with the quote form, text or WhatsApp them to 0439 729 553, or email support@pmpwa.net.au. Already have a service report or defect list? Attach that too.

Related questions

Free · Reply within one business day

Get a free second opinion on your last service report, or a second quote.

Upload it and PMP will tell you what's overdue under AS 1851, which defects are still open and what's close to the end of its life. Already have a quote? We'll give you a second one to compare.

Upload Your Report

Questions people ask

How often does a fire pump need testing?

Every month under AS 1851-2012: a diesel pump runs for at least 10 minutes and an electric pump for at least 3 minutes. Once a year it also gets a full flow test to prove it delivers the water the building was designed for.

Do you service diesel and electric pumps?

Yes. PMP services, tests, repairs and overhauls diesel and electric fire pumps, jockey pumps and their controllers, anywhere in Western Australia.

Can you take over our existing contract?

Yes. Send us the last service report and we'll pick up the schedule from there.

What's the difference between a diesel and an electric fire pump?

The difference is what drives the pump. A diesel pump runs on its own engine and fuel, so it doesn't depend on the building's power. An electric pump runs on the building's power supply. Many buildings have one of each.

Why does my jockey pump keep starting?

Usually because the system is losing pressure — a leaking valve, fitting or drain, or a pressure switch set wrong. Constant starting wears the jockey pump out and can hide a bigger leak, so the cause should be found.

Can you service our building pumps at the same visit?

Yes. Pressure, sewer and stormwater pumps in the same plant room can be done together, on one report.

My fire pump runs every test. Is that enough?

It proves the pump starts and makes pressure. It doesn't prove it can deliver water at the flow the building needs. That's what a flow test is for.